Generac 6294 30-Amp 6-10 Circuit Manual Transfer Switch Kit for Portable Generators

Generac 6294 30-Amp 6-10 Circuit Manual Transfer Switch Kit for Portable Generators Review



Generac 6294 30-Amp 6-10 Circuit Manual Transfer Switch Kit for Portable Generators Feature

  • Safely switch from utility to 30-amp portable generator power in an emergency and power critical circuits through your home?s electrical system
  • Interchangeable type circuit breakers make it easy to reconfigure, replace, or expand the circuits in your switch
  • Directly powers hard-wired appliances such as your furnace (gas/oil only), well pump, and septic pump
  • Kit includes all components and suitable for surface mounting
  • Comes with a 1-year limited warranty
The Generac 6294 30-Amp 6-10 Circuit Manual Transfer Switch Kit allows you to skip the hassle of running multiple extension cords from your generator to your appliances during a power outage. Instead, connect your Generac portable generator to a permanently installed Generac manual transfer switch. A Generac manual transfer switch allows you to safely switch from utility to portable generator power in an emergency and power critical circuits through your home’s electrical system. Use this transfer switch for 7,500-watt, 125/250-volt generators equipped with NEMA 3R L14-30 power outlets. The kit includes a 30-amp (6-10) circuit pre-wired transfer switch for surface mounting, a 10-foot 10/4 cord with L14-30 ends, wiring harness, conduit and fittings, wire connectors and installation manual. This item can be used with the GP5500, GP6500E, GO7500E, XG6500, XG7000E, XG8000E, XP6500E and XP8000E generators (XP units require a switch neutral kit). The mechanically interlocked generator and utility breakers prevent dangerous back feeding to avoid injuring utility line workers. This unit measures 9-1/4-inch wide, 11-1/8-inch high, 3-3/8-inch deep and weighs 19-pounds. The Generac 6294 30-Amp 6-10 Circuit Manual Transfer Switch Kit is backed by a 1-year limited warranty. Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators. Generac also operates three large factories that employ thousands of workers in the American Midwest.


Saturday, May 26, 2012

GenTran Ovation Series 200 Amp Utility/125 Amp Generator 38 Circuit NEMA 1 Automatic Transfer Switch For Up To 30,000 Watt Generators ATS2001D

GenTran Ovation Series 200 Amp Utility/125 Amp Generator 38 Circuit NEMA 1 Automatic Transfer Switch For Up To 30,000 Watt Generators ATS2001D Review



GenTran Ovation Series 200 Amp Utility/125 Amp Generator 38 Circuit NEMA 1 Automatic Transfer Switch For Up To 30,000 Watt Generators ATS2001D Feature

  • GenTran ovation series 200 Amp transfer switch NEMA 1 accommodates up to 38 household circuits and generators up to 30 kilowatt
  • This model is ideal for installation in new construction as the main load center in a home or business
  • Compatible with virtually any stationary generator up to 30 kilowatt; but can also be installed in retrofit application behind an existing load center
  • NEMA 1 cabinet can be flush or surface mounted indoors
  • Ul listed in US and Canada; measures 14.3 inches in width by 39 inches in height by 3.93 inches in depth
ATS2001D Features: -Accommodates up to 38 household circuits.-UL Listed in US and Canada.-Made in USA.-Part Number: ATS2001D. Specifications: -Compatible with virtually any stationary generator up to 30 kW.-For generators up to 30 kW. Dimensions: -Dimensions: 14.3'' W x 39'' H x 3.93'' D.-Weight: 44 lbs.


Wednesday, May 23, 2012

Generac 6296 60-Amp 10-16 Circuit Manual Transfer Switch Kit for Portable Generators

Generac 6296 60-Amp 10-16 Circuit Manual Transfer Switch Kit for Portable Generators Review



Generac 6296 60-Amp 10-16 Circuit Manual Transfer Switch Kit for Portable Generators Feature

  • Safely switch from utility to 60-amp portable generator power in an emergency and power critical circuits through your home?s electrical system
  • Interchangeable type circuit breakers make it easy to reconfigure, replace, or expand the circuits in your switch
  • Directly powers hard-wired appliances such as your furnace (gas/oil only), well pump, and septic pump
  • Kit includes all components and suitable for surface and flush mounting
  • Comes with a 1-year limited warranty
The Generac 6296 60-Amp 12-16 Circuit Manual Transfer Switch Kit allows you to skip the hassle of running multiple extension cords from your generator to your appliances during a power outage. Instead, connect your Generac portable generator to a permanently installed Generac manual transfer switch. A Generac manual transfer switch allows you to safely switch from utility to portable generator power in an emergency and power critical circuits through your home’s electrical system. Use this transfer switch for 12,500-watt, 125/250-volt generators equipped with NEMA 3R CS6365 power outlets. The kit includes a 60-amp (12-16) circuit transfer switch for surface or flush mounting, a 10-foot 6/4 cord with 14-50 male and CS6364 60-amp locking female ends, wiring harness, conduit and fittings, wire connectors and installation manual. This item can be used with the GP15000E, GP17500E and XG10000E generators (XP units require a switch neutral kit). The mechanically interlocked generator and utility breakers prevent dangerous back feeding to avoid injuring utility line workers. This unit measures 14-3/8-inch wide, 11-1/2-inch high, 3-3/8-inch deep and weighs 33-pounds. The Generac 6296 60-Amp 12-16 Circuit Manual Transfer Switch Kit is backed by a 1-year limited warranty. Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators. Generac also operates three large factories that employ thousands of workers in the American Midwest.


Tuesday, May 22, 2012

Generac RTSX100A3 Nexus Smart Switch 100 Amp

Generac RTSX100A3 Nexus Smart Switch 100 Amp Review



Generac RTSX100A3 Nexus Smart Switch 100 Amp Feature

  • More backup coverage with a smaller generator
  • Additional DLM Modules can manage up to four more large electrical loads (sold separately)
  • Aluminum enclosure
  • 120/240 1 NEMA 3R
Engineered with Generac's Digital Load Management (DLM) technology, the Nexus Smart Switch is the smartest transfer switch on the market. It has the ability to cycle on and off two air conditioners without adding additional components, allowing for a smaller generator to cover more circuits than when paired with a standard transfer switch.


Wednesday, April 25, 2012

Reliance Controls 20216A Pro/Tran 6-Circuit 20-Amp Generator Transfer Switch for up to 5000-Watt Generators

Reliance Controls 20216A Pro/Tran 6-Circuit 20-Amp Generator Transfer Switch for up to 5000-Watt Generators Review



Reliance Controls 20216A Pro/Tran 6-Circuit 20-Amp Generator Transfer Switch for up to 5000-Watt Generators Feature

  • Generator transfer switch for up to 5000-watt generators
  • The 18-inches flexible conduit whip attaches easily to the load center and all wires are clearly marked
  • Features a powder-coated steel cabinet with six combination 1/2-inches and 3/4-inches knockouts and resettable branch rated circuit breakers
  • Includes a covered opening to accommodate a power inlet for installation in a dry location and non-defeat able double-throw switches
  • This indoor surface-mount transfer switches are designed for fast installation in residential and commercial applications; UL listed
The safe, code-approved way to provide emergency power to your home or business during a power outage. The proper connection between a portable generator and selected circuits in a load center allows the user to efficiently and easily operate appliances such as a furnace, refrigerator, sump pump, TV, well pump, lights and more. Power can be manually transferred for each appliance independently at users choice without danger of backfeeding the electrical utility. Internal wiring compartment allows for optional hardwiring to remote power inlet boxes. Dual wattmeters monitor load in generator. Completely pre-wired with individual wires marked by circuit. Indoor surface-mount design. UL listed. 5-year limited warranty. U.S.A. Circuits (qty.): 6, Amps: 20, Watts: 5,000


Monday, April 23, 2012

GenTran 6-Circuit Outdoor Generator Transfer Switch for up to 3,750-Watt Generators R300660

GenTran 6-Circuit Outdoor Generator Transfer Switch for up to 3,750-Watt Generators R300660 Review



GenTran 6-Circuit Outdoor Generator Transfer Switch for up to 3,750-Watt Generators R300660 Feature

  • 6-circuit outdoor generator transfer switch designed for generators up to 3,750 watts
  • Uses standard, off-the-shelf circuit breakers for easy replacement or expansion
  • Aluminum construction won't rust; suitable for salt-water environments
  • Can be expanded to up to 16 circuits
  • 2-year limited warranty
The GenTran 6-circuit outdoor generator transfer switch is designed for generators up to 3,750 watts. This transfer switch can be expanded to up to 16 circuits. It uses standard, off-the-shelf circuit breakers for easy replacement or expansion and includes a L5-30 power inlet. With aluminum construction, this outdoor switch won't rust, and is suitable for salt-water environments. It accommodates arc-fault and GFCI breakers required by some jurisdictions to meet new NEC requirements. The transfer switch comes with a 2-year limited warranty. Gen-Tran 300660 The most versatile home transfer switch from Gen-Tran! This manual transfer switch offers adjustable installation and an easily expandable design. Flexibility is the name of the game with accommodations for hardwired or plug-in generator connections as well as room for up to 16 circuits! Run your refrigerator, furnace, microwave, lights, TV etc... Features: -Expandable up to 16 circuits -NEMA 1 cabinet for surface mounting indoors (pictured above) or NEMA 3R unit for outdoor applications (pictured below) -Accommodates hardwired or plug-in generator connections -UL listed with the following breakers: Siemens, Cutler Hammer-BR, Square D-HOM, GE - THQL -Code-gauge metal cabinet with flat front cover and powder coat finish -Wattmeters to help monitor generator loads -Handles both inductive and resistive loads -Branch circuit breakers and mechanically interlocked main breakers -Wiring harness with 24" of flexible conduit and wire connectors Specifications: -Number of circuits: 6 -Max Number of circuits: 16 -Max Amps @ 120V: 30 -Max Generator Watts: 3750 -Included Breakers: (3) 15Amp-1Pole, (3) 20Amp-1Pole, -NEMA configuration of Male Inlet: L5-30 -A 2-pole breaker is required in load center : 60Amp (supplied by installer) -Dimensions for Indoor Cabinet (NEMA 1): 11.5 X 14.375 X 3.375 inches -Dimensions for Outdoor Cabinet (NEMA 3R): 18 X 18 X 4 inches Gen-Tran Video Indoor/Outdoor Cabinet: Indoor (Nema 1)


Thursday, April 12, 2012

Reliance Controls 30508B Pro/Tran 8-Circuit 30 Amp Generator Transfer Switch For Up To 7,500 Watt Generators

Reliance Controls 30508B Pro/Tran 8-Circuit 30 Amp Generator Transfer Switch For Up To 7,500 Watt Generators Review



Reliance Controls 30508B Pro/Tran 8-Circuit 30 Amp Generator Transfer Switch For Up To 7,500 Watt Generators Feature

  • 8-circuit, 30 Amp transfer switch for enabling generator
  • For use with 7500-watt generator with NEMA L14-30 power outlets
  • Built-in power inlet for 30 Amp power cord connection
  • cUL listed
  • 5-year limited warranty
The Reliance Controls 8-circuit 30 Amp transfer switch is designed for use with generators up running up to 7500 watts with NEMA L14-30 power outlets. The complete turn-key kit has everything needed to make a professional transfer switch installation in a home or office, enabling the wiring system of the building to accept the full power of a portable generator. This switch also has a power inlet built into its face for connection to longer 30 Amp power cords. This unit is cUL 1008 listed and is covered by a 5-year warranty. The safe, code-approved way to provide emergency power to your home or business during a power outage. The proper connection between a portable generator and selected circuits in a load center allows the user to efficiently and easily operate appliances such as a furnace, refrigerator, sump pump, TV, well pump, lights and more. Power can be manually transferred for each appliance independently at users choice without danger of backfeeding the electrical utility. Internal wiring compartment allows for optional hardwiring to remote power inlet boxes. Dual wattmeters monitor load in generator. Completely pre-wired with individual wires marked by circuit. Indoor surface-mount design. UL listed. U.S.A. Circuits (qty.): 8, Amps: 30, Watts: 7,500, Volts: 30, UL Listed: Yes


Friday, April 6, 2012

Reliance Controls TF151W Easy/Tran Single-Circuit 15 Amp Furnace Generator Transfer Switch For Up To 1875 Watt Generators

Reliance Controls TF151W Easy/Tran Single-Circuit 15 Amp Furnace Generator Transfer Switch For Up To 1875 Watt Generators Review



Reliance Controls TF151W Easy/Tran Single-Circuit 15 Amp Furnace Generator Transfer Switch For Up To 1875 Watt Generators Feature

  • Easy-tran transfer switch is designed for the control of a single circuit, such as a forced-air furnace, in the event of a power failure
  • Single-circuit 15 ampere furnace transfer switch for use with 15-ampere generator
  • Connects forced-air furnace to portable generator with any standard grounded extension cord
  • 18-inches aluminum conduit allows easy connection
  • 5-year limited warranty; UL listed
The Reliance Controls single-circuit 15 Amp furnace transfer switch is designed for use with generators with 15 Amp power outlets. It controls a single circuit, such as a forced-air furnace, in the event of a power failure, connecting it to a portable generator. The attached 18-inch flexible aluminum conduit is pre-wired and allows the unit to be easily connected at the circuit breaker panel, the furnace, or at any point in between. It can be used on any 15 Amp 120-volt forced-air furnace circuit. Simply plug a standard grounded extension cord into a power outlet on your generator and into the built-in plug on the transfer switch. It includes an indicator light, which illuminates the area around its switch during a power outage. This unit is UL listed and is covered by a 5-year limited warranty.


Thursday, March 29, 2012

Reliance Controls TTV2005C Panel/Link 36-Circuit 200 Amp Utility/50 Amp Generator Transfer Switch For Up To 12,500-Watt Generators

Reliance Controls TTV2005C Panel/Link 36-Circuit 200 Amp Utility/50 Amp Generator Transfer Switch For Up To 12,500-Watt Generators Review



Reliance Controls TTV2005C Panel/Link 36-Circuit 200 Amp Utility/50 Amp Generator Transfer Switch For Up To 12,500-Watt Generators Feature

  • 50 to 200 Amp utility subpanel for use with 12,500-watt generators
  • Capable of replacing standard, full 200 Amp service panel
  • Features heavy-duty copper bus
  • Includes a 200 Amp main circuit breaker interlinked with 30 Amp to 125 Amp generator circuit breaker
  • 5-year limited warranty
The Reliance Controls 50-200 Amp utility subpanel is designed for use with generators up to 12,500 watts. It can replace a standard, full 200 Amp service panel as a generator-ready full panel. It includes a 200A main circuit breaker interlinked with 30 Amp to 125 Amp generator circuit breaker. The interlinked circuit breakers keep the generator isolated from the utility at all times, even with the cover or deadfront removed. It features a heavy-duty copper bus. This unit is suitable for service entrance and provides for 36 branch circuits. It is covered by a 5-year warranty. TTV2005C Features: -Transfer panel. -Panel/Link TTV includes a 200A main circuit breaker interlinked with 30A - 125A generator circuit breaker. -Interlinked circuit breakers keep the generator isolated from the utility at all times, even with the cover or dead front removed. -TTV features a heavy-duty copper bus. -TTV is suitable for service entrance and provides for 36 branch circuits. -Dual wattmeters, for balancing generator load, are optional. -Maximum generator input: 50 amps @ 125/250 VAC. -Overall dimensions: 39.25'' H x 14.5'' W x 4'' D.


Sunday, March 25, 2012

Reliance Controls TRC1006D Panel/Link Generator Transfer Switch for Up to 15,000-Watt Generators, 12-Circuit 100 Amp Utility/60 Amp

Reliance Controls TRC1006D Panel/Link Generator Transfer Switch for Up to 15,000-Watt Generators, 12-Circuit 100 Amp Utility/60 Amp Review



Reliance Controls TRC1006D Panel/Link Generator Transfer Switch for Up to 15,000-Watt Generators, 12-Circuit 100 Amp Utility/60 Amp Feature

  • Panel link generator transfer switch
  • Interlinked circuit breakers, isolating generator utility
  • Can be used as a main panel; 60 to 100 ampere utility subpanel for use with 15, 000-watt generators
  • UL listed for outdoor use; heavy-duty, 20 ampere cord
  • 5-year limited warranty
The Reliance Controls 60-100 Amp utility subpanel is designed for use with generators running up to 15,000 watts. It features interlinked circuit breakers that keep the generator isolated from the utility at all times, even with the cover or deadfront removed. It is service entrance rated and may be used as a main panel or a sub-panel. This unit comes without a power inlet or wattmeter. It is UL listed and covered by a 5-year warranty. For generators up to 15,000 Watts and utility input of 100 Amps, this panel can be used as a smaller main panel for a home or cabin, or as a subpanel for a larger building. Interlinked circuit breakers keep the generator isolated from the utility at all times. Accommodates 12 to 20 common circuit breakers to control a variety of appliances and devices. Heavy-duty steel cabinet with steel door covering circuit breakers. Indoor surface or flush-mount design. UL listed. 5-year limited warranty. U.S.A. Factory shipped. Circuits (qty.): 12 - 20, Amps: 60 - 100, Watts: 15,000, UL Listed: Yes


Saturday, March 3, 2012

GenTran 200660 PowerStay 20 Amp Manual Generator Transfer Switch

GenTran 200660 PowerStay 20 Amp Manual Generator Transfer Switch Review



GenTran 200660 PowerStay 20 Amp Manual Generator Transfer Switch Feature

  • Highly versatile manual transfer switch for 6 circuits, 20 amps, and generators up to 5,000 watts
  • Expand up to 16 circuits as your needs change
  • Accommodates hardwiring to generator or installing via plug-in cord
  • Can be conveniently flush or surface mounted
  • Includes 2 15 Amp 1-pole breakers, 2 20 Amp 1-pole breakers, and 1 2-pole 20 amp breaker
The Gen/Tran PowerStay manual transfer switch is a highly versatile switch designed for 6 circuits, 20 Amps, and generators up to 5,000 watts. Plus, as your family or business needs change, this product can expand up to 16 circuits, increasing its range of use. The cabinet can be conveniently flush or surface mounted indoors, and the design accommodates either hardwiring to a generator or installing via a plug-in cord. The standard branch circuit breakers make for easy replacement and expansion, allowing you to reconfigure the product to suit your needs. This transfer switch features a L14-20 male power inlet and dual watt-meters to help balance generator loads. Included in the design are two 15 Amp 1-pole breakers, two 20 Amp 1-pole breakers, and one 2-pole 20 Amp breaker; the transfer switch accepts Arc Fault and GFCI breakers. To use this transfer switch, a 60 Amp main breaker must be installed in the existing load center. This product is listed to UL standard 1008. 200660 - Gen-Tran PowerStay 20 Amp 120/240V 5000 watt 6 circuit indoor manual transfer switch w/ L1420 inlet


Friday, February 24, 2012

GenTran 3028 8-Circuit 30 Amp Transfer Switch For Up To 7500-Watt Generators

GenTran 3028 8-Circuit 30 Amp Transfer Switch For Up To 7500-Watt Generators Review



GenTran 3028 8-Circuit 30 Amp Transfer Switch For Up To 7500-Watt Generators Feature

  • 30-amp 8-circuit transfer switch for use with up to 7,500-watt generator
  • Powers up essential circuits using 5,000-watt generator during a power outage or emergency
  • Accommodates 8 to 10 household circuits
  • Can be expanded to up to 10 circuits using standard circuit breakers
  • 2-year limited warranty
The GenTran 30 Amp 8-circuit transfer switch for up to 7,500-watt generators includes everything you'll need to install a generator transfer switch for safe, convenient portable generator hookup. Power up your essential circuits using a 5,000-watt generator (continuous watts) during a power outage or emergency. It accommodates 8-to-10 household circuits like your furnace blower (gas only), refrigerator and kitchen circuits, well pump, lights, and television. If your needs change, your installer can easily expand this transfer switch to up to ten circuits just by adding more circuit breakers. The enclosure can be surface mounted indoors, and allows hardwired or plug-in generator connections. Because it was designed with off-the-shelf circuit breakers you don't have to search high and low for replacements, and your installer can reconfigure the breaker combinations to suit your family's needs.

This transfer switch includes a L14-30 male power inlet and a dual watt meters to help you balance generator loads to prolong generator life. The kit comes with two 15 Amp 1-pole breakers, two 20 Amp 1-pole breakers, one 2-pole 20 Amp breaker, and one 2-pole 30 Amp breaker. A 60 Amp 2-pole main breaker is required in existing load center (not included). This kit comes with a 2-year limited warranty.


Thursday, February 23, 2012

Generac RTS14EZA1 EZ Switch 14-circuit Load Center

Generac RTS14EZA1 EZ Switch 14-circuit Load Center Review



Generac RTS14EZA1 EZ Switch 14-circuit Load Center Feature

  • Switch 14 circuit load center
  • 30-feet prewired conduit for connecting the transfer switch to the external connection box
  • 2-feet prewired conduit for moving circuits from the main panel to the transfer switch
  • Prewired external connection box with a weatherproof conduit
  • Switches are housed in a steel NEMA 1 enclosure, with electrostatically applied and baked powder paint
The Generac EZ Switch with 14 circuit load center is ideal for homeowners who choose to backup selected circuits rather than the whole house. Pre-wired for the easiest installation on the market.


Tuesday, February 21, 2012

Generac RTSX200A3 Nexus Smart Switch 200 Amp

Generac RTSX200A3 Nexus Smart Switch 200 Amp Review



Generac RTSX200A3 Nexus Smart Switch 200 Amp Feature

  • More backup coverage with a smaller generator
  • Additional DLM Modules can manage up to four more large electrical loads (sold separately)
  • Aluminum enclosure
  • 120/240 1 NEMA 3R
Engineered with Generac's Digital Load Management (DLM) technology, the Nexus Smart Switch is the smartest transfer switch on the market. It has the ability to cycle on and off two air conditioners without adding additional components, allowing for a smaller generator to cover more circuits than when paired with a standard transfer switch.


Monday, February 20, 2012

GenTran 301060 PowerStay 30 Amp Manual Transfer Switch

GenTran 301060 PowerStay 30 Amp Manual Transfer Switch Review



GenTran 301060 PowerStay 30 Amp Manual Transfer Switch Feature

  • Highly versatile manual transfer switch for 10 circuits, 30 amps, and generators up to 7,500 watts
  • Expand up to 16 circuits as your needs change
  • Accommodates hardwiring to generator or installing via plug-in cord
  • Can be conveniently flush or surface mounted
  • Includes 3 15 Amp 1-pole breakers, 3 20 Amp 1-pole breakers, 1 2-pole 20 amp breaker and 1 2-pole 30 Amp breaker for your water heater
The Gen/Tran PowerStay manual transfer switch is a highly versatile switch designed for 10 circuits, 30 amps, and generators up to 7,500 watts. Plus, as your family or business needs change, this product can expand up to 16 circuits, increasing its range of use. The cabinet can be conveniently flush or surface mounted indoors, and the design accommodates either hardwiring to a generator or installing via a plug-in cord. The standard branch circuit breakers make for easy replacement and expansion, allowing you to reconfigure the product to suit your needs. Housed in a NEMA 3R-rated aluminum cabinet, this transfer switch features a L14-30 male power inlet. Included in the design are three 15 Amp 1-pole breakers, three 20 Amp 1-pole breakers, one 2-pole 20 Amp breaker and one 2-pole 30 Amp breaker for your water heater; the transfer switch accepts Arc Fault and GFCI breakers. To use this transfer switch, a 60 Amp main breaker must be installed in the existing load center. This product is listed to UL standard 1008. 301060 Indoor/Outdoor Cabinet: Indoor (Nema 1) The most versatile home transfer switch from Gen-Tran! This manual transfer switch offers adjustable installation and an easily expandable design. Flexibility is the name of the game with accommodations for hardwired or plug-in generator connections as well as room for up to 16 circuits! Run your refrigerator, furnace, microwave, lights, TV, well pump, home office, water heater, garage door, security system etc... Features: -Expandable up to 16 circuits -NEMA 1 cabinet for surface mounting indoors or NEMA 3R unit for outdoor applications -Accommodates hardwired or plug-in generator connections -UL listed with the following breakers: Siemens, Cutler Hammer-BR, Square D-HOM, GE - THQL -Code-gauge metal cabinet with flat front cover and powder coat finish -Wattmeters to help monitor generator loads -Handles both inductive and resistive loads -Branch circuit breakers and mechanically interlocked main breakers -Wiring harness with 24'' of flexible conduit and wire connectors Specifications: -Number of circuits: 10 -Max Number of circuits: 16 -Max Amps @ 240V: 30 -Max Generator Watts: 7500 -Included Breakers: (3) 15Amp-1Pole, (3) 20Amp-1Pole, (1) 20Amp-2Pole, (1) 30Amp-2Pole -NEMA configuration of Male Inlet: L14-30 -A 2-pole breaker is required in load center : 60Amp (supplied by installer) -Dimensions for Indoor Cabinet (NEMA 1): 11.5 X 14.375 X 3.375 inches -Dimensions for Outdoor Cabinet (NEMA 3R): 18 X 18 X 4 inches


Friday, February 17, 2012

GenTran R200660 20-Amp 6-Circuit Outdoor Generator Transfer Switch for Generators up to 5000 Watts

GenTran R200660 20-Amp 6-Circuit Outdoor Generator Transfer Switch for Generators up to 5000 Watts Review



GenTran R200660 20-Amp 6-Circuit Outdoor Generator Transfer Switch for Generators up to 5000 Watts Feature

  • UL Listed and meets National Electrical Code requirements
  • Can be expanded to up to 16 circuits - just upgrade it instead of replacing it!
  • Uses standard, off the shelf circuit breakers for easy replacement or expansion
  • Aluminum construction won't rust and is suitable for salt-water environments
  • Accommodates arc-fault and GFCI breakers required by come jurisdictions to meet new NEC requirements
200660 Indoor/Outdoor Cabinet: Indoor (Nema 1) The most versatile home transfer switch from Gen-Tran! This manual transfer switch offers adjustable installation and an easily expandable design. Flexibility is the name of the game with accommodations for hardwired or plug-in generator connections as well as room for up to 16 circuits! Run your refrigerator, furnace, microwave, lights, TV, well pump, home office etc... Features: -Expandable up to 16 circuits -NEMA 1 cabinet for surface mounting indoors or NEMA 3R unit for outdoor applications -Accommodates hardwired or plug-in generator connections -UL listed with the following breakers: Siemens, Cutler Hammer-BR, Square D-HOM, GE - THQL -Code-gauge metal cabinet with flat front cover and powder coat finish -Wattmeters to help monitor generator loads -Handles both inductive and resistive loads -Branch circuit breakers and mechanically interlocked main breakers -Wiring harness with 24'' of flexible conduit and wire connectors Specifications: -Number of circuits: 6 -Max Number of circuits: 16 -Max Amps @ 240V: 20 -Max Generator Watts: 5000 -Included Breakers: (2) 15Amp-1Pole, (2) 20Amp-1Pole, (1) 20Amp-2Pole -NEMA configuration of Male Inlet: L14-20 -A 2-pole breaker is required in load center : 60Amp (supplied by installer) -Dimensions for Indoor Cabinet (NEMA 1): 11.5 X 14.375 X 3.375 inches -Dimensions for Outdoor Cabinet (NEMA 3R): 18 X 18 X 4 inches


Sunday, February 5, 2012

GenTran 300660 30-Amp 6-Circuit Manual Transfer Switch for Generators up to 3750-Watt

GenTran 300660 30-Amp 6-Circuit Manual Transfer Switch for Generators up to 3750-Watt Review



GenTran 300660 30-Amp 6-Circuit Manual Transfer Switch for Generators up to 3750-Watt Feature

  • UL Listed and meets National Electrical Code requirements
  • Can be expanded to up to 16 circuits-just upgrade it instead of replacing it
  • Uses standard, off the shelf circuit breakers for easy replacement or expansion
  • Versatile design allows for flush or surface mounting next to your load center and accommodates hardwiring or plug-in generator connections
  • Accommodates arc-fault and GFCI breakers required by come jurisdictions to meet new NEC requirements
300660 Indoor/Outdoor Cabinet: Indoor (Nema 1) The most versatile home transfer switch from Gen-Tran! This manual transfer switch offers adjustable installation and an easily expandable design. Flexibility is the name of the game with accommodations for hardwired or plug-in generator connections as well as room for up to 16 circuits! Run your refrigerator, furnace, microwave, lights, TV etc... Features: -Expandable up to 16 circuits -NEMA 1 cabinet for surface mounting indoors (pictured above) or NEMA 3R unit for outdoor applications (pictured below) -Accommodates hardwired or plug-in generator connections -UL listed with the following breakers: Siemens, Cutler Hammer-BR, Square D-HOM, GE - THQL -Code-gauge metal cabinet with flat front cover and powder coat finish -Wattmeters to help monitor generator loads -Handles both inductive and resistive loads -Branch circuit breakers and mechanically interlocked main breakers -Wiring harness with 24'' of flexible conduit and wire connectors Specifications: -Number of circuits: 6 -Max Number of circuits: 16 -Max Amps @ 120V: 30 -Max Generator Watts: 3750 -Included Breakers: (3) 15Amp-1Pole, (3) 20Amp-1Pole, -NEMA configuration of Male Inlet: L5-30 -A 2-pole breaker is required in load center : 60Amp (supplied by installer) -Dimensions for Indoor Cabinet (NEMA 1): 11.5 X 14.375 X 3.375 inches -Dimensions for Outdoor Cabinet (NEMA 3R): 18 X 18 X 4 inches